MONITOR AFx™ Director V4.1 User's Guide
500-9041 v4.1
Inputs
- Fire Required
and
Fire Circuit:
Whether or
not the "Fire" input is being used, and the type
of circuit/wiring associated with it.
- Bypass Required
and
Bypass Circuit:
Whether or not the "Bypass" (manual
override) input is being used, and the type of
circuit/wiring associated with it. (Triggering
the bypass input enables the call button for all
floors for this elevator.)
- Panic Required
and
Panic Circuit:
Whether
or not the "Panic" input is being used, and the
type of circuit/wiring associated with it. This
input triggers a "panic"-type of alarm.
- Floor Button to Enable:
This identifies the
action to occur in the event of a fire (enable a
floor call-button, all floors, etc.).
Floors
-
This screen lists all defined floors in the system.
Under "Control Access To", select the ones that
can be accessed from this elevator (lift) cab.
(i.e., that are physically connected.)
Tip:
The floor relay board number/address, and relay
numbers are listed for your convenience.
Attention:
Floors need to have been defined in the
same relative order as per the common relay-wiring
order for all elevator cabs (such as from lowest to
highest). To define system floors, refer to the floor
configuration topic (to follow).