500-9041 v4.1
Welcome Report Control Admin
Sys Config
Tech-Ref
177
Card Version (Version-Number)
This feature requires
≥
V3.2
panel firmware
and
≥
V1.5
door/elevator controller module
firmware. For an additional setting, refer to
"AutoUpdate Card Version", under
Special
(to follow).
- Version Required:
This
enables/disables version number
checking (allows fixed-ID cards to be
re-issued if lost or stolen).
- Position:
The starting position of the
version number (1-40).
- Length:
The length of the version
number (MS: 1-2; W: 1-20).
Card ID
- Position:
The starting position of card ID
number (1-40);
- Length:
The length of card ID number (MS: 4-9;
W: 1-32).
32-Bit Cards: Supported with panel firmware
≥
V3.2
,
and
door/elevator controller module firmware
≥
V1.5
(prev. 20 bit / 6 digits).
V3.2
panels: MaxID=999999999;
≥
V3.31
Panels:
MaxID=4
294
967
295.
- Bits per Card:
The length of the card data in
bits (Wiegand), or characters (magnetic stripe).
This can be up to 40.
- Bits per Character
(magstripe only)
:
The number
of bits used to identify each character of data on
a magstripe card (future use; fixed as
4
).
Odd Parity
These settings pertain to odd-parity checking, which
helps to identify card 'misreads'.
- Position:
The position of the odd-parity
'checksum' (1-40);
-Start:
The starting position of the data being
checked for odd-parity (1-40);
- Length:
The number of digits being checked for
odd-parity (1-40).
Even Parity
These settings pertain to even-parity checking, which
helps to identify card 'misreads'.
- Position:
The position of the even-parity
'checksum' (1-40);
-Start:
The starting position of the data being
checked for even-parity (1-40);
- Length:
The number of digits being checked for
even-parity (1-40).
Special
(Miscellaneous Items)
-Door Fallback Mode:
Cards to be granted
access if the door controller module is unable
to communicate with the main MONITOR AFx
panel database:
•
None:
No cards/tokens accepted;
•
Valid Token Format:
All readable
cards/tokens accepted;
•
Valid Site Code:
All cards/tokens with the
correct site code will be granted access;
•
10 Fall-back Users:
Only the users who are
assigned as 'FallBack Users'. For details,
refer to "Fall-Back Users...".
-Unlock All Doors On Fire Alarm:
If selected,
all doors in all areas associated with this
panel will automatically unlock when a fire
alarm is detected by this panel.
-AutoUpdate Card Version:
For fixed-ID
cards with a version number, this sets how re-
issued cards are to be handled.
= Grant access to a card with higher version
number, and update the version number for the
specific user automatically;
= Only cards that match the version number for
each user will be granted access (must update
manually when a card is re-issued).
To set the initial/actual version number for specific
card(s), refer to the section on "Users".
For additional related settings, refer to "Card Version"
(previous). Panel Version: This feature requires
≥
V3.2
panel firmware.